Skip to main content

Filling In the Energy Balance Energy Input Tab

The Energy Input tab contains the selection of calculation input Attributes for the flow and transfer elements in the model. These Attributes contain the energy measurements, as well as the energy tolerances, of every measurement. The selected values and tolerances are the inputs to the Sigmafine Reconciliation engine.Figure 342: Energy Balance Configuration - Energy Input tab

Note that the output values you use for the parameters listed in the following table must be valid ones specified in the Element templates.

Energy Input Tab

ParameterDefault Attribute NameDescription
Specific Energy MeasurementMeasuredSpecificEnergy 1Measured specific energy.
Specific Energy ToleranceSpecificEnergyTolerance 1The tolerance, in units of specific energy, corresponding to the measurement of specific energy
Energy MeasurementMeasuredEnergyMeasured total energy.
Energy ToleranceEnergyToleranceThe tolerance, in units of Energy, corresponding to the measurement of total energy.
Energy Balance FlagEnergyBalanceFlagThe Attribute flagging participation in the Energy balance.
1 The unit of measure of specific energy is determined in the table SF_EnergyBalance parameter named “QuantityUOM.” The preconfigured value for this parameter in UOM of Energy.